Composite UHPC Decked Tub Beam: Long Spans, Heavy Loads, and Flat Floors
- Gregory Lucier (North Carolina State University)
- Khaled Al-Sakaji (North Carolina State University)
- Mostafa Abo El-Khier (e.Construct)
- Maher K. Tadros (e.Construct)
Abstract
This paper describes development of a long-span precast member to facilitate parking under residential and commercial multistory light-framed buildings. A precast podium system provides an elevated level above parked vehicles to support up to four stories. Conventional precast podiums require a large number of precast elements, many connections, and column lines through the parking area, which are considered an inconvenience and a safety hazard for drivers. The research proposes and prototypes a 70 ft. (21.34 m) span composite decked beam consisting of a prestressed ultra-high-performance concrete (UHPC) tub girder made composite with a conventional concrete deck in a secondary precasting operation. Utilizing the proposed composite UHPC decked beams as primary spanning elements in a podium designed by the researchers eliminated internal columns. Using large, decked beams also reduced the precast piece-count by over 80% as compared to a traditional design, saving construction time and costs. The system does not require a cast-in-place topping for a flat top surface, further enhancing construction speed and reducing cost. Large midspan web openings accommodate utilities. Design, fabrication, and testing of the proposed beam are presented. Flutes in the UHPC top flange facilitate composite action along with projecting mild steel reinforcement, while structural capacity in flexure and shear rely on prestressing strands, distributed steel fibers, and minimal mild steel reinforcement for bursting. Production of a full-scale prototype specimen included a two-stage casting process with a wet-cast deck applied to a prestressed UHPC tub. The deck was cast 4 ft (1.22 m) wide for the testing but is envisioned as 12 ft (3.66 m) wide on a real project. Results from a test to failure demonstrate exceptional performance in flexure despite initial difficulties manufacturing a prototype UHPC tub with the intended beam-deck interface. Results demonstrate flexure capacity was controlled by strand rupture, not by the accidentally weakened UHPC-deck interface, as described later. This result confirms that the proposed composite UHPC decked beam can support the necessary design loads.
Keywords: UHPC, Composite Decked Beam, Heavy Loads, Flat Floors, Flexural Test, Podium
How to Cite:
Lucier, G., Al-Sakaji, K., Abo El-Khier, M. & Tadros, M. K., (2026) “Composite UHPC Decked Tub Beam: Long Spans, Heavy Loads, and Flat Floors”, International Interactive Symposium on Ultra-High Performance Concrete Papers 4(1): 30, 1-8. doi: https://doi.org/10.21838/uhpc.25654
Downloads:
Download PDF
View PDF
164 Views
56 Downloads