Ultra-High Performance Concrete (UHPC) is characterized by its high compressive and cracking strengths. Due to the addition of a large quantity of steel fibers, UHPC also exhibits high tensile strength and strain-hardening properties. However, these tensile characteristics are influenced by the steel fiber content and specimen geometry. This paper reports on the verification of the tensile properties of ultra-rapid hardening UHPC, which was developed as a material for deck slab overlay. Uniaxial tensile tests were conducted on specimens containing 1.5, 2.0, and 2.5 vol.% steel fibers and on specimens with heights of 100, 50, and 30 mm (3.94, 1.97, and 1.18 inches). The results confirmed that increasing the steel fiber content improves tensile properties and that specimens with heights of 50 mm (1.97 in) and 30 mm (1.18 in) exhibit high tensile properties.

Keywords: Overlay, UHPC, Uniaxial tensile testing, Tensile properties, Steel fiber content, Specimen heights

How to Cite:

Aoki, S., Tomii, T. & Sasaki, K., (2026) “Effects of Steel Fiber Content and Specimen Dimensions on the Tensile Properties of UHPC”, International Interactive Symposium on Ultra-High Performance Concrete Papers 4(1): 10, 1-6. doi: https://doi.org/10.21838/uhpc.25638