Skip to main content

Shear Strengthening of Champlain Bridge Slabs with UHPC

Authors
  • Jean-Philippe Charron (Polytechnique Montréal)
  • Mahdi Ben Ftima (Polytechnique Montréal)
  • Antoine Houdoin (Polytechnique Montréal)

Abstract

This paper presents an investigation on the shear behavior of ultra-high performance fiber reinforced concrete (UHPC) strengthenings applied to slabs from the decommissioned Pont Champlain Bridge. Two original slabs and three UHPC-strengthened slabs were tested with various shear-to-span ratios (a/d) with the repairs under tension. Experiments highlight the UHPC-strengthenings’ performance in comparison to the original slabs. With the decrease in a/d ratio from 4 to 2.5, the UHPC-strengthened slabs showed higher capacity, lower peak displacement, and reduced post-peak ductility. The shear strength for a/d=4.0 was 3.1 times greater than that of the original slabs and became 4.1 times greater for a/d=2.5. These results were related to the modification of the shear failure mode according to the a/d ratio. A ductile shear failure controlled by the tensile strength of the UHPC layer occurred for a/d=4 and 3.25, while a brittle shear failure with a delamination of the repair interface was observed for a/d=2.5.

Keywords: UHPC, Shear strengthening, Bridge slab, Shear span, Shear capacity, Failure mode

How to Cite:

Charron, J., Ftima, M. B. & Houdoin, A., (2026) “Shear Strengthening of Champlain Bridge Slabs with UHPC”, International Interactive Symposium on Ultra-High Performance Concrete Papers 4(1): 1, 1-8. doi: https://doi.org/10.21838/uhpc.25630

Downloads:
Download PDF
View PDF

324 Views

68 Downloads

Published on
2026-06-13

Peer Reviewed