None

Pulsed eddy current response to general corrosion in concrete rebar

Authors: I. Eddy (Royal Military College of Canada) , P. R. Underhill (Royal Military College of Canada) , T. W. Krause (Royal Military College of Canada) , J. Morelli (Queens University)

  • Pulsed eddy current response to general corrosion in concrete rebar

    None

    Pulsed eddy current response to general corrosion in concrete rebar

    Authors: , , ,

Abstract

Corrosion of carbon steel rebar in concrete structures, such as highway bridges and buildings, has a direct impact on their structural integrity, since the rebar provides the tensile strength within the structure. Rebar strength depends on the remaining effective radius of a given rod. Examination of long-time decay, up to 0.1 s, in the transient response of Pulsed Eddy Current (PEC), was examined as a potential method to quantify general corrosion in ferromagnetic rebar. The transient response of a coaxial solenoidal drive-receive coil pair, oriented parallel to the rebar axis, was analyzed over a range of distances into the concrete (liftoff) and rebar radii. At long times, the single exponential decay constant was largely independent of lift-off. A power law relationship for the characteristic decay time, consistent with long-time diffusion of electromagnetic fields into a rod, was observed. The intercept of a best-fit line to measured voltage decay, decreased exponentially with lift-off, and maintained a measurable response up to 110 mm distance for a 25 mm (1 in) diameter rebar. Reported results demonstrate potential for PEC to quantify remaining cross-sectional area of rebar in concrete structures, accounting for distance of rebar within concrete.

How to Cite:

Eddy, I., Underhill, P. R., Krause, T. W. & Morelli, J., (2019) “Pulsed eddy current response to general corrosion in concrete rebar”, Review of Progress in Quantitative Nondestructive Evaluation .

Downloads:
Download PDF

98 Views

149 Downloads

Published on
03 Dec 2019
Peer Reviewed
License